Elos Auto Top Off: Setup and Calibration Steps for Reef Tanks
Learn how to set up and calibrate an elos auto top off for your reef tank, with step-by-step instructions, troubleshooting tips and common mistakes to avoid.
Updated November 2026
An elos auto top off, or ATO, keeps your reef tank’s water level steady by adding fresh water whenever evaporation drops the level below a set point. In this guide you will learn how to plan the installation, position the sensor, set the reservoir and pump, calibrate the system, and check that it works before you walk away from the tank. The process takes about an hour for most setups, and the steps below apply whether you run a nano or a larger display.
Why an Auto Top Off Matters for Reef Tanks
Water evaporates from every reef tank, and the water leaves as pure H2O while the salt stays behind. When the level drops by hand-topping sessions that happen too rarely, salinity climbs, and even a small rise can stress corals, fish and invertebrates. An ATO removes the guesswork by replacing evaporated water on a schedule set by the sensor, not by your memory. Most reefers use reverse osmosis/deionized water in the reservoir, never tap water, because dissolved minerals in tap water build up and change the chemistry of the system over time.
Shopping for one? See our guide: 6 Best Aquarium Auto Top Off System Picks for Reef Tanks (2026).
The main benefit is stability. Salinity usually moves less when the top-off is automatic, and the tank’s water level stays consistent, which helps protect your skimmer, sump and return pump from running dry. If you are still building your system, it helps to read a general overview of Marine Auto Top Off: How to Set Up and Calibrate an ATO for Reef Tanks first, since many of the same principles carry over.
What You Need Before You Start
Gather everything before opening the box, so you are not hunting for a fitting halfway through. Most elos-style systems are sold as a kit with a float or conductivity-based sensor, a controller or relay, a pump, tubing and a reservoir. Check the kit’s manual for the exact parts, since layouts differ between models.
- RO/DI water in a clean, covered reservoir sized for at least several days of evaporation
- The ATO pump, tubing and check valve (to prevent siphoning back into the reservoir)
- The sensor or float, plus mounting clips or suction cups
- The controller, power supply and outlet for the pump
- A marker or piece of tape to indicate the target water line
- A calibrated hydrometer or refractometer for checking salinity afterward
- A small towel and a container to catch drips during installation
Step-by-Step Setup
Step 1: Choose the Right Location for the Sensor
Mount the sensor in the sump or display where the water is calm. Turbulence from a return pump outlet, a powerhead or a wavemaker can cause false readings, so keep the sensor away from direct flow. Many reefers mount it in a separate sump chamber or a small compartment that is connected to the main water body, which keeps the sensor in still water while the level stays representative of the tank.
Step 2: Mount the Reservoir and Pump
Place the reservoir at a height that lets the pump draw water freely, and keep the reservoir lid closed to limit evaporation and contamination. Mount the pump on a stable surface and keep the tubing as short and straight as practical. Install the check valve in the line between the pump and the tank so water cannot siphon back when the pump is off.
Step 3: Run the Tubing and Wiring
Route the tubing from the reservoir to the sump or display, making sure there are no sharp bends that restrict flow. Keep electrical connections well above the waterline, and use a drip loop on each power cord so water runs down and away from the outlet. Never place the controller where splashes can reach it.
Step 4: Set the Target Water Level
Fill the tank to the level you want to maintain, then mark that line on the glass or with tape. Set the sensor so it triggers the pump at a point slightly below this line, not at the surface, so the pump does not run constantly. A common approach is to set the trigger a few millimeters below the target so small fluctuations do not cause repeated cycling.
Step 5: Calibrate the System
Calibration is where most setups succeed or fail. With the system powered, run the pump manually until the water reaches the target line, then stop it and confirm the sensor is not already triggered. Next, let the water drop slightly through evaporation, or lower it by a small amount, and watch the pump start and stop at the intended points. Adjust the sensor position or setting until the cycle matches your target. Record the settings in a notebook so you can restore them after cleaning or relocation.
Step 6: Test and Monitor
Run the system through at least one full cycle before leaving it unattended. Check that the pump stops on time, that the reservoir level is dropping at a reasonable rate, and that no water is spilling. Measure salinity after the first day and again after a week. Expect small swings as the system settles, then confirm readings stay within your target range.
Troubleshooting Common Problems
| Problem | Likely cause | Fix |
|---|---|---|
| Pump runs continuously | Sensor triggered by surface turbulence or misplaced | Move the sensor to calmer water and recalibrate |
| Pump never turns on | Sensor not reaching trigger point, or loose connection | Check wiring, test the sensor manually, lower the trigger slightly |
| Water level overshoots | Trigger set too high or pump runs too long | Lower the trigger point and reduce run time if adjustable |
| Salinity rising | Reservoir contains salt or tap water, or sensor issue | Use RO/DI water only and verify the sensor reading |
| Reservoir empties too fast | Leak in tubing or fittings | Inspect joints and replace damaged tubing |
If you own a specific model and the fixes above do not resolve the problem, check the manufacturer’s guide for your exact unit. For a deeper look at a common failure pattern, see JBJ Auto Top Off Not Working: Troubleshooting Steps That Fix It.
Common Mistakes
- Using tap water or untreated saltwater in the reservoir, which leads to mineral buildup and salinity swings
- Placing the sensor in a high-flow area that creates false triggers
- Skipping the check valve and allowing siphoning back into the reservoir
- Setting the trigger right at the surface, which causes frequent cycling
- Leaving the reservoir uncovered, letting dust and salt creep settle inside
- Assuming the system works without a test run or salinity check
Tips for Long-Term Reliability
- Clean the sensor monthly with a soft brush to remove salt film and algae
- Keep a spare pump and tubing on hand, since these parts wear out first
- Check the reservoir level weekly and refill before it runs low
- Write down your calibrated settings so any reset is quick
- Test salinity at the same time each week to spot drift early
Recommended gear
A few supplies make the job easier and help the system run smoothly. None of these are required, but they are common choices among reef keepers.
- Instant Ocean Reef Crystals is a widely used salt mix for reef systems, useful when you need to mix saltwater for water changes rather than for the ATO itself. View on Amazon
- Milwaukee Instruments refractometer lets you measure salinity accurately at the tank, which is the best way to confirm your ATO is holding stable levels. View on Amazon
- Tunze Osmolator is a well-known auto top-off system that many reefers use as a reference point when comparing controllers and sensors. View on Amazon
FAQ
How often should I refill the ATO reservoir?
Refill it whenever the level approaches the bottom of the reservoir. Evaporation rates vary with room humidity, temperature and tank size, so many reefers check the reservoir every few days and keep a few days of supply on hand.
Can I use tap water in my auto top off?
No. Tap water contains dissolved minerals and sometimes chlorine or chloramine, which accumulate in the tank over time. Use reverse osmosis or deionized water instead.
Why does my ATO keep running all the time?
The sensor is usually reading turbulence, sitting in a moving water stream, or is set too close to the surface. Move it to calmer water, then recalibrate the trigger point.
How do I know if my ATO is working correctly?
Watch the cycle for at least one full run. The pump should start at your trigger point and stop at the target line, and salinity should stay stable across several days.
Should the ATO reservoir be covered?
Yes. A cover keeps dust, debris and airborne salt from contaminating the water and helps limit evaporation from the reservoir itself.
Can an auto top off cause salinity problems?
It can if the reservoir water is not pure or the sensor fails. If you notice salinity rising, test the reservoir water and confirm the sensor is functioning before adjusting anything else.
What if I have a power outage?
The ATO will stop during an outage, so water will not be replaced until power returns. Keep a close eye on the water level after an outage and top off manually if needed. For delicate tanks, consider a battery backup for the controller.
Should I consult a professional for my setup?
For routine installation, the manufacturer’s instructions and a careful calibration are usually enough. If you are working with complex plumbing or electrical connections in your home, consult a licensed electrician or plumber.
Conclusion
A well-calibrated elos auto top off keeps your reef tank’s water level and salinity steady without daily attention. Choose a calm sensor location, use pure reservoir water, calibrate carefully, and test the full cycle before walking away. Check the system regularly, and your corals and fish will benefit from the consistency.
Related reading
- Tunze Osmolator 3 Nano Auto Top Off: Setup and Calibration in 7 Steps
- Tunze Osmolator 3 Auto Top Off: Setup and Calibration Guide
- Tunze Auto Top Off: Setup, Calibration and Troubleshooting Guide (2026)
Ready to choose one?